|
plastic dryer |
|
plastic dryer |
Troubleshooting and maintenance related to injection dryer! |
source:Plastic pellet dryer Author:plastic dryer time:2020年10月10日 10:05:25 |
plastic dryer,
Dehumidifying dryer,
Plastic pellet dryer,
plastic Dehumidifying dryer
1. Regenerative windmill overload Overload of regenerative windmill appears above the touch screen After checking the regeneration filter, the air inlet and the wind turbine, check the regeneration fan contactor to see if the fan is damaged 2. Dry windmill overload Dry windmill overload appears above the touch screen Check the dehumidification filter, the suction and dehumidification air outlet and return air pipeline, or the dehumidification windmill 3. The electric heating temperature is too high Regeneration temperature is too high The electric heating temperature is too high above the touch screen Regeneration temperature is too high Switch the main switch to "OFF" for three minutes and then switch to "ON" 4. The regeneration temperature is too high The regeneration temperature is too high above the touch screen Check whether the regeneration filter is blocked, check the EGO adjustment position, and check whether the regeneration fan is normal 5. Burned fuse A blown fuse appears above the touch screen Check the control circuit for short circuit, replace the fuse 6. Phase error Phase error appears on the top of the touch screen Change the power phase 7. The temperature of regenerative electric heating is too low For ten minutes, the electric heating temperature cannot rise above 180℃ Check the load of the power supply and check whether the current is normal. If it is abnormal, it means that the electric heater is burned out and needs to be replaced 8. The dew point is not low enough Bad drying Check whether the dehumidifier circuit and cooling water temperature, regeneration temperature and regeneration temperature, gear reducer and filter are unblocked 9. The suction is not smooth No suction or no suction Check whether the air pressure source is open, check whether the suction machine filter is blocked, check whether the suction machine setting is improper, and whether the air cut/cut valve is leaking 10. The dryer temperature cannot be increased Temperature is too low or no temperature Check whether the temperature controller of the dryer is set normally, check whether the dryer electromechanical heat pipe is normal, and check whether the dryer electromechanical heat contactor is normal 11. Overload of suction fan Suction fan overload appears on the touch screen Check whether the adjustment position of the hopper temperature protector is at 2508451; 12. Dry fan overload Dry fan overload appears on the touch screen Check whether the circulating filter is blocked or the circulating air pipeline is blocked, whether the relay/fan is damaged 13. The regeneration temperature is too low The regeneration temperature is too low on the touch screen Check whether the regeneration temperature is adjusted to 180℃, whether the electric contactor is normal, and whether the electric heater is burned out plastic dryer, Dehumidifying dryer, Plastic pellet dryer, plastic Dehumidifying dryer |
Dehumidification dryer | gravimetric blender | granules mixing machine |
Links: | plastic dryer | Dehumidifying Dryer | gravimetric blender | beryllium copper | Central feeding system |
contact us: | Mr. Li | QQ: | 1251609588 | Phone: | +8613669807274 | E-mail: | wto-btb@wto-btb.com |
Ask for a quotation |
WhatsApp +8613669807274 |
Wechat +8613669807274 |
wto-btb@wto-btb.com |
Tel: +8613669807274 |
SMS: +8613669807274 |
Website name:Plastic dryer Copyright:Plastic dryer |
Search industry:plastic dryer,Dehumidifying dryer,Resin dryer,plastic Dehumidifying dryer ©2007-2029 @ |